Model Number: DW-150L100#5064-#4155
Brand Name: Herald
Key Specifications/Special Features:
Characteristicsoftheproductfunction:1.Refrigeration system:Optimized cascade refrigeration technology, SECOP compressor to reach high efficiency refrigeration effectSpecially designed heat exchanger, heat transfer high efficient, save energyCFC-free overall situ polyurethane foaming insulationCFC-free refrigerant2. Temperature control:Microprocessor control, digital display of inner temperature, the inner temperature can be adjustable at the range of -70 to 150°CLCD running status and alarm information
Over temperature alarm system, set the alarm temperature as requirements
3. Safety control:
Malfunction alarms: high temperature alarm, low temperature alarm, Sensor failure, Power failure alarm, Door jammed, low voltage of backup battery
Two alarming methods: buzzer alarming and digital flashing alarming
Protection function: power-on delay, time between stops
4.Ergonomic design:
Safety lock in door, preventing unauthorized access
Wide voltage design from 187V to 242V
Maintenance free condenser design
25mm access port
Pressure-balanced port design, easy to open the door
Heavy type caster and locking adjustable screw, easy to move and fix
| Model |
DW-150W100 |
| Technical Data |
Cabinet type |
Chest |
| Climate class |
N |
| Cooling type |
direct cooling |
| Defrost mode |
manual |
| Refrigerant |
CFC-free |
| Performance |
Cooling performance (°C) |
-150 |
| Temperature range |
-70 to 150°C |
| Control |
Controller |
microprocessor |
| Display |
LED+LCD |
| Material |
Interior |
galvanized steel powder coating |
| Exterior |
galvanized steel powder coating |
| Electrical data |
Power supply (V/Hz) |
220/50 |
| Power (W) |
1400 |
| Electrical current (A) |
8.5 |
| Dimensions |
Capacity (L/Cu.Ft) |
100/3.5 |
| Net/gross weight (approx) |
254/310 (kg) |
| Interior dimensions (W*D*H) |
440x440x510 (mm) |
| Exterior dimensions (W*D*H) |
1240x840x954 (mm) |
| Packing dimensions (W*D*H) |
1320x920x1075 (mm) |
| Container load (20'/40'/40'H) |
6/13/13 |
| Functions |
High/low temperature |
Y |
| Remote alarm |
Y |
| Hot condenser |
Y |
| Power failure |
Y |
| High/low voltage |
Y |
| Sensor error |
Y |
| Low battery |
Y |
| High ambient temp |
Y |
| Door ajar |
N/A |
| Lockage |
Y |
| Inner LED light |
N/A |
| Accessories |
Caster |
Y |
| Foot |
N/A |
| Test hole |
Y |
| Shelves/inner doors |
-/1 |
| Temperature recorder |
optional |
| USB interface |
optional |
| Rs232/485 interface |
optional |
| CO2 backup system |
optional |
| LN2 backup system |
optional |
| Racks and boxes |
optional
|